X-Y torch lifter
|
|
|
Limit switches
|
Upper and lower inductive proximity sensors
|
|
Max. Z-axis speed Max. Z-axis stroke
|
200 ipm (5.0 m/min) 8 inches (200 mm)
|
|
Total weight with torch mounting block
|
18.25 pounds (8.4 kg)
|
|
Positioning resolution
|
0.001 inch (0.025 mm)
|
|
THC control function
|
|
|
Set point resolution Set point range
|
0.5 volt 50-300 volts
|
|
Maximum control accuracy
|
±1 0.5 volts
|
|
Voltage feedback (divider)
|
1/40.95 of arc voltage
|
|
Initial piercing height control function
|
On/off signal provided by CNC
|
|
Initial piercing height mode
|
Set cutting height; pierce height is automatically computed
|
|
Set point resolution Set point range Pierce height factor Work contact sensing Work clear Pierce delay range Pierce delay resolution Machine acceleration delay Machine acceleration delay
|
0.010 inch (0.10 mm) 0.020–1.00 inch (0.5–25.4 mm) 1 to 3 times the cutting height Ohmic contact and/or motor torque Loss of Ohmic contact 0 to 5 sec 0.010 sec 0.00 to 1.00 sec Resolution 0.010 sec
|
|
Initial piercing height stall force
|
1–10 Relative setting
|
|
Initial piercing height speed
|
1–10 Relative setting
|
|
Homing speed
|
1–10 Relative setting
|
|
Miscellaneous features
|
Ability to be synchronized with parallel THC systems Electrically floating interface Machine safety interlock System fully complies with the following standards and directives: CSA 22.2 #60 UL 551 EN 60974-1 EN 50199 EN 55011 Low voltage directive EMC directive
|